1. What type of oil is used in a gas turbine engine?.


A. Synthetic.


B. Phosphate Ester.


C. Mineral.


2. After placing an engine in an M.V.P envelope.


A. check humidity indicator after 12 hours.


B. check humidity indicator after 24 hours.


C. check humidity indicator after 48 hours.




3. On a vapour proof cocoon, there is a.


A. temperature indicator.


B. moisture indicator.


C. humidifier.


4. When an installed engine is not to be used for a period of up to 7 days.


A. it is necessary to inhibit the engine.


B. it is only necessary to blank off all apertures.


C. run the engine as prescribed in the Flight Manual.



5. Installed engines must be re-preserved after preservation at least every.


A. six weeks.


B. six days.


C. six months.


6. On storage of an engine, the desiccant is.


A. looked at within 24 hrs if its blue its OK.


B. looked at 24 hrs later if its blue its OK.


C. looked at 24 hrs later if blue it should be replaced.



7. After placing an engine into storage, details would be recorded in.


A. Technical Log.


B. Engine log book.


C. Aircraft log book.


8. When storing an engine the fuel system is to be inhibited. How is this done?.


A. Remove plugs rotate engine then add oil.


B. Rotate engine whilst adding oil then remove plugs.


C. Add oil leaving plugs in.



9. An engine in storage for 7 days should.


A. have storage oil placed in engine.


B. be run twice in that week.


C. be fitted with covers and blanks and apertures covered.


10. On a (VP) cocoon bag, if the humidity indicator turns pink/lilac.


A. desiccant is effective and does not need changing.


B. desiccant is ineffective and needs changing.


C. desiccant is changed weekly.



ABOVE QUESTIONS WITH ANSWERS



1. What type of oil is used in a gas turbine engine?.




A. Synthetic.




B. Phosphate Ester.




C. Mineral.




Ans : Synthetic.























2. After placing an engine in an M.V.P envelope.




A. check humidity indicator after 12 hours.




B. check humidity indicator after 24 hours.




C. check humidity indicator after 48 hours.




Ans : check humidity indicator after 24 hours.
















3. On a vapour proof cocoon, there is a.


A. temperature indicator.


B. moisture indicator.


C. humidifier.


Ans : moisture indicator.










4. When an installed engine is not to be used for a period of up to 7 days.


A. it is necessary to inhibit the engine.


B. it is only necessary to blank off all apertures.


C. run the engine as prescribed in the Flight Manual.


Ans : it is only necessary to blank off all apertures.










5. Installed engines must be re-preserved after preservation at least every.


A. six weeks.


B. six days.


C. six months.


Ans : six months.










6. On storage of an engine, the desiccant is.


A. looked at within 24 hrs if its blue its OK.


B. looked at 24 hrs later if its blue its OK.


C. looked at 24 hrs later if blue it should be replaced.


Ans : looked at 24 hrs later if its blue its OK.










7. After placing an engine into storage, details would be recorded in.


A. Technical Log.


B. Engine log book.


C. Aircraft log book.


Ans : Engine log book.










8. When storing an engine the fuel system is to be inhibited. How is this done?.


A. Remove plugs rotate engine then add oil.


B. Rotate engine whilst adding oil then remove plugs.


C. Add oil leaving plugs in.


Ans : Remove plugs rotate engine then add oil.










9. An engine in storage for 7 days should.


A. have storage oil placed in engine.


B. be run twice in that week.


C. be fitted with covers and blanks and apertures covered.


Ans : be fitted with covers and blanks and apertures covered.










10. On a (VP) cocoon bag, if the humidity indicator turns pink/lilac.


A. desiccant is effective and does not need changing.


B. desiccant is ineffective and needs changing.


C. desiccant is changed weekly.


Ans : desiccant is ineffective and needs changing.